Magnetometer flux data and vibration measurements help to accurately determine RPM. The magnetic data provides a stable…
Remote monitoring detected a faulty gearbox in a cooling tower, causing bearing damage. The customer was informed and o…
High vibration and noise levels at the motor were caused by an unbalanced fan impeller and a cracked structure. Cleanin…
Vibration analysis requires careful consideration of time waveforms and spectra, as misinterpretations can lead to inac…
A case study identifies a new vibration pattern for a damaged belt in a rotary machine, characterized by dominant 2XBRF…
Predictive online monitoring identified a failure in the gearbox input gear, preventing major damage and production los…
Constellium’s Ravenswood, WV plant faced critical failures due to improper lubrication practices. By implementing condi…
Understanding equipment failure effects and costs is crucial for developing maintenance strategies that maximize reliab…
Misalignment, often underestimated, is a major source of chronic machine problems with severe long-term consequences. I…
Defect Torque Arm with Improper Clamping
Vibration measurement on a centrifugal pump indicated a defective bearing, prompting a dismantling for overhaul. Despit…
LP compressor performance degradation was observed six months after commissioning, with efficiency dropping from 65% to…