Bernard Boueri
Structural Natural Frequency Problem at a Dewatering Pump

Dewatering pump vibration levels were reduced from 0.9 ips pk to below 0.1 ips pk by stiffening the pedestal, shifting …

1 min read
Read More
Post image
Omar M. Abdulhammed Soliman
Clay Crasher Fan Belt Failure

Clay Crasher Fan Belt Failure

1 min read
Read More
Post image
Felipe Pimenta
Detailed Analysis of Two Stage Planetary Gearbox Vibration

A two-stage planetary gearbox experienced bearing and bolting failures due to an overload. After repairs, a no-load spi…

1 min read
Read More
Post image
Budi Priyohutomo
Slow Speed Machine Bearing Fault with Envelope

In order to achieve precise monitoring, the machine operates within a shaft rate +/- 3 RPM. In fact, the bearing faults…

1 min read
Read More
Post image
Diky Aldilla
Diesel Generator Base Main Frame Crack

A 5MW Diesel Generator experienced high axial vibration (52mm/s) due to a 75cm crack beneath cylinder #2 on the main fr…

1 min read
Read More
Post image
Kadir KOÇAK
Fan Unbalance and Motor Coupling Breaking Case Study

ODS analysis and visual inspections revealed significant corrosion and wear problems at the base connections of the equ…

1 min read
Read More
Post image
Martec
Mining - Investigation of High Risk Level Electrical Defects

Martec was appointed to provide condition-based maintenance solutions for the medium voltage electrical assets at a pla…

2 min read
Read More
Post image
Martec
Renewable Energy - Defect Findings of Medium Voltage Type “C” Terminations at Solar Plants

Martec conducted in-time condition assessments on 800 Type “C” terminations at solar plants in South Africa, identifyin…

2 min read
Read More
Post image
Martec
Mining - Seismic Vibration

A mining client faced complaints of residential property damage due to mining activities. Martec conducted a vibration …

2 min read
Read More
Post image
Martec
Improved MV Substation Reliability and Safety with Condition Monitoring

An electrical utility client faced challenges with an ageing infrastructure, high electricity demand, and overloaded as…

2 min read
Read More
Post image
Martec
Manufacturing - 33/11kV Transformer T9 Partial Discharge Online Assessment

Martec identified damaged cables and excessive oil leaks in Transformer T9, posing a risk of failure. Martec installed …

2 min read
Read More
Post image
Martec
Manufacturing - 6.6kV Substation Motor Terminations Partial Discharge

Martec conducted an online assessment using PDFSA technology to evaluate the condition of MV components in a 6.6kV subs…

2 min read
Read More