Pump Bearing Fault Detection

A critical pump bearing was detected to have damage using Acoem’s Falcon data collector and a Connection Technology CenterTREA330 accelerometer. The customer was able to plan a change to a spare bearing before the pump failed, preventing production downtime.

Like what you see? Sign up to share your own knowledge, like posts, and engage with the community!

It's been a whirlwind of a year, transitioning from Royal Air Force (RAF) to civilian life with PFE Limited, it's been a year of new experiences and I have learnt so much with the help of Jake Ford & Paul Ford.

I thought I would share one of the more recent faults that I have detected this year, which I am particularly proud of.

This bearing is off a pump which is critical to this customers process. There is no standby unit to rely on, if this fails, the production stops.

This was the first set of data that we have on this asset, with no previous trend data to refer to, using Acoem's Falcon data collector and a Connection Technology CenterTREA330 accelerometer.

Fortunately, our customer responded quickly to this analysis and planned in a change to a spare before this pump could become an issue.

Here, at the PFE workshop, the pump was stripped down, inspected and the bearing cut open. Here the damage was clearly seen in the outer race of the bearing.

This damage was not causing a problem now, however it would have progressed and became a problem in the future. Without a routine condition monitoring survey being carried out, this asset would have likely failed in-situ and cost the customer production downtime.

Additional Images
Post Information
Category: Vibration Case Study
Language: English
Reading Time: 1 min
Tags
pump bearing fault outer race
Original Authors
Dan Williams
Shared By
Reliability

Login to view profile

Join Our Community

Sign up to share knowledge, engage with posts, and connect with experts.