Vibration analysis using FFT identified gear defects and clearance issues, enabling planned equipment shutdown.
Equipment showed evolution in vibration levels in the typical acceleration parameter of backlash and gear defect.
the use of FFT was fundamental in the analysis.
Sidebands of sidebands indicate the clearance between the gears.
Cascade with the before and after intervention, global evidence before and after and the spectrum evidence.
along with the gears of how they were operating.
It was identified with vibration sensors, which allowed us to monitor the evolution and schedule the shutdown of the equipment in a planned and organized manner.
always arrive first.