RMS 130 Housing Worm reducer experienced gear fractures and cracked bearings.
Heat plant heating boiler mixer screw reducer
RMS 130 Housing Worm reducer.
Measurement trend tracking with SKF CMDT391 from 0.10 mm/s to 1.16mm/s
The value of 5.90 GE increased from 3.16 GE.
The reducer was removed.
Gear fractures in the reducer Cracked bearings in the worm screw were seen in the gap.