Agitator Motor Coupling Defect

An exponential increase in agitator motor parameters indicated a coupling defect, but NR12 prevented inspection. The technician, anticipating imminent failure, contacted the shift coordinator and mechanics to remove the protection and stop the equipment, confirming the defective coupling.

Like what you see? Sign up to share your own knowledge, like posts, and engage with the community!

Bringing another case here...

Today it's about not ''sitting'' on the problem, and going after solutions to save an asset.

During routine collection, an exponential increase was identified in all parameters of an agitator motor. By the spectra, with multiple rotation harmonics and 1x high in speed, it indicated a coupling defect, but NR12 prevented its inspection. That's where the technician's feeling comes in, I could simply open a note and warn the customer but I knew that the failure of this equipment was about to occur.

I contacted the shift coordinator, requested support from the mechanics to remove the protection, along with the support of the operation to stop the equipment and thus the defective coupling was evidenced!