Fan Motor Bearing Fault

Fan motor vibration and bearing noise are unacceptable, a BPFO defect was identified, and bearing replacement is recommended.

Like what you see? Sign up to share your own knowledge, like posts, and engage with the community!

Catch of the week ✨️💡

High vibration of the fan motor (NGA = 6 g) and high background noise at both fan bearings. The vibratory condition of the fan is considered unacceptable.
Following a vibration analysis, a BPFO-type bearing defect was identified.
I recommend replacing the turbine bearings during the next planned shutdown.