Greasing Effect on Bearing Fault Frequencies

BPFO and BPFI peaks were observed at the DE of Condensate extraction Pump 2A and 4A. After greasing, the peaks dropped significantly and a spectrum analysis indicated the number of balls on the bearing.

Like what you see? Sign up to share your own knowledge, like posts, and engage with the community!

During the last routine data collection, BPFO & BPFI peaks were observed at the DE of Condensate extraction Pump 2A & 4A. On 2A peaks were up to 60 g's pk-pk while on 4A peaks were at 55 g's pk-pk (Waveform).
Customer was advised to grease motor bearing. Shortly after greasing, peaks dropped to 8 g's pk-pk and 15 g's pk-pk respectively (waveform). After greasing, looking at the spectrum for 4A, peaks at BPFI with 1X sideband became obvious along BPFO, when you add both peaks together, it gives an interger number of 9 (3.73x + 5.27x = 9), indicating the number of balls on the bearing are 9. Below are attached photos

At Machinery Consultation and Services Pty Ltd we do due deligence to avert failures and prolong the life of your equipment...

Data were collected using the Emerson AMS 2140 vibration analyzer

Additional Images
Post Information
Category: Vibration Case Study
Language: English
Reading Time: 1 min
Tags
grease bearing motor
Original Authors
Faith Ekpoboriyoma
Shared By
Reliability

Login to view profile