Mechanical Looseness on a High-Speed Equipment

High-speed equipment analysis detected 1x dominant hillock and 1x 3.5 g.s vibration signals.

Like what you see? Sign up to share your own knowledge, like posts, and engage with the community!

3000 RPM direct coupling connection high-speed equipment mechanical slack.
As a result of the analysis, 1x dominant hillock followed the vertical vibration signals coming at 50 Hz and detecting bolt elongation on the equipment legs with 1x 3.5 g.s vibration signals.