3000 RPM direct coupling connection high-speed equipment mechanical slack.
As a result of the analysis, 1x dominant hillock followed the vertical vibration signals coming at 50 Hz and detecting bolt elongation on the equipment legs with 1x 3.5 g.s vibration signals.
EMERSON 2140