Agitator Pinion Gear Failure

Portable sensor and platform enabled efficient temperature and vibration monitoring, leading to accurate diagnostics. This allowed for the identification of a vibration alarm, preventing major failures and eliminating corrective and unexpected production stoppages.

Like what you see? Sign up to share your own knowledge, like posts, and engage with the community!

In gear transmissions, the first damage is usually received by small pinions. Since they are desired to receive the first damage during the manufacturing phase, the material hardness and properties are selected differently than other gears.
Sometimes it may be due to manufacturing or assembly errors. In the example in this post, it is the Agitator pinion gear failure detected in vibration measurements. As a result of the failure, the agitator was sent to service for maintenance.

Additional Images
Post Information
Category: Vibration Case Study
Language: English
Reading Time: 1 min
Tags
Agitator gear pinion fault
Original Authors
Özgür BİLGİÇ
Shared By
Reliability

Login to view profile

Join Our Community

Sign up to share knowledge, engage with posts, and connect with experts.