Predictive Maintenance identified an abnormal acceleration value of 7.87 g in the receiving area, indicating tooth breakage in the conveyor input gear. The recommended action is gearbox replacement.
🔧 Failure identified monitoring route – Punctual action of the Predictive
The Predictive Maintenance team was called by maintenance to carry out a punctual collection in the receiving area.
During data analysis, an abnormal value of 7.87 g was identified in acceleration. The signal in the time domain showed characteristic impacts of tooth breakage and clearances in the conveyor input gear.
📉 Technical Evidence:
Measuring unit: g
Current value: 0.6 g
Alarm value: 2.6 g
Recorded peak: 7.87 g
📌 Possible Cause: Instant overload
🛠️ Recommended Action: Gearbox Replacement
This is another example of how predictive maintenance acts strategically even outside the scheduled routines, contributing to avoid critical failures and ensure the continuity of industrial processes.